Chapter 7 Application Tutorial Installation and Operation Manual
7-26 IP DSLAM and WiMAX Backhauling over SDH/SONET Egate-100 Ver. 4.0
³ To connect to the terminal:
1. Connect the male 9-pin D-type connector of CBL-DB9F-DB9M-STR straight
cable available from RAD to the CONTROL connector.
2. Connect the other connector of the CBL-DB9F-DB9M-STR cable to an ASCII
terminal.
Terminal cables must have a frame ground connection. Use ungrounded cables
when connecting a supervisory terminal to a DC-powered unit with floating
ground. Using improper terminal cable may result in damage to supervisory
terminal port.
CONTROL
Egate-100
RDY
ALM
12
LIN K
MNG-ETH
LIN K
ACT
GbE
ACT
1 2
STM-1/OC-3STM-1/OC -3
LINK
SYNCSYNC
DCE
Figure
7-35: CONTROL Connector
Connecting to the Network Management Station
Egate-100 is connected to an NMS via an 8-pin RJ-45 connector designated
MNG ETH. Refer to
Appendix A
for the connector pinout.
³ To connect to an NMS:
Connect Egate-100 to a hub or switch using a straight cable
Or;
Connect Egate-100 to a network interface card using a cross cable.
When connecting Fast Ethernet cables longer than 30 meters (98 feet), it is
recommended to use shielded cables.
CONTROL
Egate-100
RDY
ALM
12
LIN K
MNG-ETH
LIN K
ACT
GbE
ACT
1 2
STM-1/OC-3STM-1/OC -3
LINK
SYNCSYNC
DCE
Figure
7-36: Fast Ethernet Management Connector