RAD Data comm 100 Specifikace Strana 215

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 318
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 214
Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Egate-100 Ver. 4.0 Monitoring Performance 5-11
³ To clear all bridge port statistics:
1. In the Bridge Monitoring menu, select Clear Statistics.
A confirmation message is displayed:
Clear all the bridge port statistics. Are you sure? (y/n)
2. Type Y to confirm your request.
All bridge port statistics are cleared.
Egate-100
Main Menu> Monitoring> Bridge> Statistics
Bind To ... (GbE)
Rx Correct Frames ... (543)
Rx Correct Octets ... (36969)
Rx FCS Errors ... (0)
Tx Correct Frames ... (210)
Tx Correct Octets ... (14686)
Tx Drop ... (0)
1. Port Number[2 - 128] ... (3)
Please select item <1 to 1>
F - Forward Port; B - Backward Port
ESC-prev.menu; !-main menu; &-exit
Figure
5-15. Bridge Statistics Menu
Table
5-3. Bridge Statistics Parameters
Parameter Description
Rx Correct Frames The total number of correct frames received
Rx Correct Octets The total number of octets (bytes) received
Rx FCS Errors Total number of frames received with a valid length, but with
invalid FCS and an integral number of octets (not applicable for
logical ports)
Tx Correct Frames The number of frames successfully transmitted
Tx Correct Octets The number of octets successfully transmitted
Tx Drop The number of congested dropped frames.
Viewing Radius Statistics
³ To display Radius statistics:
Navigate to Main Menu > Monitoring > System > Radius Statistics.
The Radius Statistics menu appears as illustrated in
Figure
5-16
.
Zobrazit stránku 214