Quick Start Guide Installation and Operation Manual
Starting a Terminal Session for the First Time
³ To start a terminal configuration session:
1. Connect an ASCII terminal to the CONTROL port on the front panel. The
default settings are as follows:
Baud Rate: 115,200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None.
2. To optimize the view of the system menus, do the following:
Set the terminal emulator to VT100.
If you are using HyperTerminal, set the terminal mode to the 132-column
mode.
3. Power up Egate-100 and verify that the PWR LED on the front panel is on.
4. Verify the unit's correct startup by observing one of the following:
From the ASCII terminal verify that the Self-Test was successfully
completed
Check the ALM LED on the front panel of the unit:
Off – No alarms
On – Device alarm.
5. If the ALM LED is on, check the physical connections.
6. Press any key to display the Login screen.
7. Enter the user name and the password and proceed with the management
session.
The default user names are su and user. The default password is 1234. Only su
has permission to modify configuration parameters and download new software
versions.
Configuring Basic Parameters
The Quick Setup menu allows you to configure mandatory elements. For
additional information on parameters and the menus, refer to
Chapter 4
.
Configuration via the Quick Setup Menu
Note
³ To configure the required parameters using the Quick Setup menu:
1. Navigate to Main Menu > Configuration > Quick Setup.
The Quick Setup appears as illustrated below.
2 Configuring Egate-100 Egate-100 Ver. 4.0