Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-18 Detecting Problems Egate-100 Ver. 4.0
Code Event Description
101 AIS Path alarm indication signal
102 EED Path EED
103 TIM TIM at HVC level
104 PLM Signal lable payload mismatch
105 LOM Loss of multiframe
106 RDI Remote defect indication at path level
107 SD Signal degrading at path level
108 Event Threshold Path ES Number of detected error seconds in a path
109 Event Threshold Path SES Number of severe error seconds in a path
exceeds the specified threshold.
110 Event Threshold Path CV Number of coding violations in a path exceeds
the specified threshold.
111 Event Threshold Path UAS Number of unavailable seconds in a path
exceeds the specified threshold.
112 Event Threshold FE-Path ES Number of error seconds in a path at the far
end exceeds the specified threshold.
113 Event Threshold FE-Path SES Number of severe error seconds in a path at the
far end exceeds the specified threshold.
114 Event Threshold FE-Path CV Number of coding violations in a path at the far
end exceeds the specified threshold.
115 Event Threshold FE-Path UAS Number of unavailable seconds in a path at the
far end exceeds the specified threshold.
Table
5-12. LVC Alarms List
Code Event Description
120 LOP Loss of pointer at tributary level
121 AIS Alarm indication signal at tributary level
122 EED EED at tributary level
123 TIM TIM at LVC level
124 PLM Signal lable payload mismatch at tributary level
125 RDI Remote defect indication at tributary level
126 SD Signal degrading at tributary level
127 Event Threshold VT ES Number of error seconds in a VT exceeds the
specified threshold.
128 Event Threshold VT SES Number of severe error seconds in a VT exceeds
the specified threshold.