Appendix A Connection Data Installation and Operation Manual
A-20 Power Connection FCD-E1LC Ver. 1.0
A.7 Power Connection
Connector Data
FCD-E1LC units have one standard IEC three-pin socket for connection to power
(either DC or AC). Connector wiring is listed in
Table A-16
, together with a view of
the connector itself.
Table A-16. Power Connector Pin Functions
Pin
Function with AC Power
Source
Function with DC Power
Source
RE TU RN POWER
100 48240 60
/
/VAC VDC
1 Return (0V) Ground (0V)
2 Chassis (Frame) Ground Chassis (Frame) Ground
3 Phase (Power) -48/-60 VDC
AC/DC Adapter Plug
The connection of the FCD-E1LC to a DC power source is made by means of a
special AC/DC adapter plug. This adapter, which plugs into the FCD-E1LC power
connector, has internal wire terminals for connecting the leads of the DC power
cable. See description of AC/DC adapter plug and instructions for connecting a DC
power cable in the RAD
Supplement SUP-930: DC Power Supply Connection –
AC/DC Adapter (AD) Plug
.