Installation and Operation Manual Chapter 4 Configuring a Flow-Based Point-To-Point Application
RV-EMS/NGN LA-210 Ver. 1.5 Configuring LA-210 4-15
³ To add a CoS profile:
1. In the CoS Profiles list, click <Add>.
The Add CoS Profiles dialog appears with an ID assigned.
Figure
4-16. Adding CoS Profiles
2. Assign a name to the mapping, for example CoSProfile_no_1 and leave the
ingress priority method set to 802.1p.
3. Under Mapping, set User Priority 4 to CoS Mapping 3 and User Priority 7 to
CoS Mapping 6 respectively.
To modify the CoS mapping values, select the CoS Map value under User
Priority 4 and then click <CoS>.
A list with available CoS values appears.
4. Select 6 from the list.
5. Click <Set>.
The new CoS Mapping value is set.
6. Repeat this procedure for the second User Priority value.
³ To link flow 1 to the newly created CoS profile:
1. In the LA-210 View window, select the System view.
2. On the menu bar, click Configuration > Flows.
The Flow dialog appears (
Figure
4-17
).