RAD Data comm LA-210 Uživatelský manuál Strana 43

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 158
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 42
User’s Manual Chapter 3 Configuration Management
RV-EMS/NGN LA-210 Setting the Operational Parameters 3-13
³ To configure the PCS parameters:
1. In the SHDSL Layers screen, click Edit and then select PCS…
The PCS screen appears.
2. Configure the parameters as needed and then click Set.
Figure
3-10. PCS Parameters Screen
Table
3-6. PCS Parameters
Parameter Possible Values / Remarks
PCS
Index of the SHDSL PCS (physical coding sublayer)
PCS 1
Read-only
Name
Assigns a name to the PCS
Default: PCS
Lines
Number of available SHDSL lines
Up to 4
Read-only
Administrative Status
Sets the administrative status
Up
Down
Default: Up
OAM (EFM)
Single segment (link) OAM according to 802.3ah for remote management and
fault indication, including remote loopback and MIB parameters retrieval.
Enable
Disable
Default: Disable
Zobrazit stránku 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 157 158

Komentáře k této Příručce

Žádné komentáře