RAD Data comm HCD-E1 Specifikace Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 232
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-40 HCD-E1 Command Set Description 11/01/00 19:23
PM OF PORT - A
CRC ERROR EVENTS = 0
CRC AVG ERR EVENTS = 0
CURRENT ES = 0
CURRENT UAS = 0
CURRENT SES = 0
CURRENT BES = 0
CURRENT LOFC = 0
CURRENT CSS = 0
CURRENT TIMER = 176
For the description and allowed range of the parameters, see E1
Performance Monitoring in Section 5.3.
2. Press any key to see the next screen:
Note
HCD-E1 displays this screen only if it has been working over 15 minutes after
power-up.
INTERVAL 01 ES = 000 UAS = 000 BES = 000 SES = 000 LOFC = 000 CSS = 000
INTERVAL 02 ES = 000 UAS = 000 BES = 000 SES = 000 LOFC = 000 CSS = 000
INTERVAL 03 ES = 001 UAS = 034 BES = 000 SES = 044 LOFC = 001 CSS = 001
24 HOUR ES = 1
24 HOUR UAS = 34
24 HOUR SES = 44
24 HOUR BES = 0
24 HOUR LOFC = 1
24 HOUR CSS = 1
24 DEGRADE MIN = 0
LAST 24 DEGRADE MIN = 0
24 INTERVAL = 03
Note
If the CRC-4 function is disabled, HCD-E1 displays an error message: ILLEGAL
COMMAND FOR CURRENT PORT MODE.
DSP ST CH
Purpose
Display status information for a specified channel.
Syntax
DSP ST CH X
Zobrazit stránku 123