Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-6 Detecting Errors Optimux-34 Ver. 2.81
The E1 screen is displayed.
Monitoring>Physical Layer>E1
1. Device Number > (Local)
2. Port Number[1 – 16] > (1)
Administrative Status > (Up)
Operation > (Up)
Alarm Indication > (Normal)
Test Indication > (Off)
Alarms > (Unmasked)
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
5-8. Physical Layer E1 Screen
³ To display the status of the V.35 port:
From the Physical Layer menu, select V.35.
The V.35 screen is displayed.
Monitoring>Physical Layer>V.35
1. Device Number > (Local)
Administrative Status > (Up)
Operation > (Up)
Alarm Indication > (Normal)
Test Indication > (Off)
Alarms > (Unmasked)
>
Please select item <1 to 1>
ESC-prev.menu; !-main menu; &-exit 1 user(s)
Figure
5-9. Physical Layer V.35 Screen
V.35 is visible only if the port is installed.
5.2 Detecting Errors
³ To perform diagnostic loops:
From the Main menu (see
Figure 4-2
), choose Diagnostics.
The Diagnostics menu is displayed (see
Figure
5-10
).
Note