FOMi-40
Fiber Optic Modem with Remote Management
Indicators
PWR (green) – On when power is on
RTS (yellow) – On when DTE activates
Request To Send
TD (yellow) – On when steady SPACE is
transmitted;
Blinks when data is transmitted
RD (yellow) – On when steady SPACE is
received;
Blinks when data is received;
Not active when the RLB is active
DCD (yellow) – On when a valid received
line signal is present
TEST (red) – On when in two loopback
modes and/or when BERT is activated
ERR (red) – On when alarm is initiated;
Blinks when an error is detected in BER
tests
Power Supply
AC: 115 or 230 VAC (±10%), 47–63 Hz
DC: –48 VDC (±10%) or 24 VDC (±10%)
Power Consumption
• FOMi-40 AC model – 5 VA
• FOMi-40 DC model – 3.5W
• FOMi-40C single-modem card – 2.9W
• FOMi-40CD double-modem card –
5.6W (both modems with IR-ETH/QN)
Physical
FOMi-40 standalone
Height: 4.4 cm (1.7 in)
Width: 24.0 cm (9.6 in)
Depth: 19.3 cm (7.6 in)
Weight: 1.4 kg (3.1 lb)
PCU (Portable Control Unit)
Height: 2.5 cm (0.98 in)
Width: 13.0 cm (5.12 in)
Depth: 6.5 cm (2.56 in)
Weight: 220 g (0.49 lb)
Card
Fits in a single slot of the LRS–24
chassis
Environment
Temperature: 0
o
to 50
o
C (32
o
to 122
o
F)
Humidity: up to 90%, non-condensing
Table 2. FOMi-40
Fiber O
tic Interface Characteristics
Wavelength
[nm]
Fiber Type
[μm]
Transmitter
Type
Typical Output
Power
[dBm]
Receiver
Sensitivity
[dBm]
Typical Max.
Range
[km] [mi]
850 62.5/125
multimode
LED/VCSEL -18 -38 4.8 3.0
1310 9/125 single
mode
Laser -12 -40 50 31
1550 9/125 single
mode
Laser -12 -40 100 62