Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-46 HCD-E1 Command Set Description 11/01/00 19:23
HRPT
Indicates whether there is an H-RPT repeater on the
HDSL link, and the side of H-RPT to which your
HCD-E1 is connected.
DOESN’T
EXIST
There is no H-RPT on the HDSL link.
NTU_SIDE Your HCD-E1 is configured as central
LTU_SIDE Your HCD-E1 is configured as remote
HRPT SOFTWARE VER
H-RPT software version (this field is displayed only
if there is H-RPT on the HDSL link)
HRPT HARDWARE VER
H-RPT hardware version (this field is displayed
only if there is H-RPT on the HDSL link)
DSP TS
Purpose
Display the allocation of the time slots of the HDSL signal.
Syntax
DSP TS
Use
To display the time slot information, type:
DSP TS<CR>
A typical display is shown below:
TIME SLOT MAPPING OF MAIN LINES
==============================
TS: 0123456789
TYPE: NC NC NC NC NC NC NC CH2 NC NC
TS: 10 11 12 13 14 15 16 17 18 19
TYPE: NC NC CH1 NC NC NC NC NC NC NC
TS: 20 21 22 23 24 25 26 27 28 29
TYPE: NC NC SL NC NC NC DEDIC NC NC NC
TS: 30 31
TYPE: NC NC