Rad-data-comm ASMi-31 Uživatelský manuál Strana 55

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 66
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 54
ASMi-31 Installation and Operation Manual Appendix C. X.21 Interface Module
EXT Mode C-3
JP 2
INT/RCV
clock setting
EXT
clock setting
Connector DB-15
EXT
Figure C-3 Location of Jumper JP2 in the IR-X.21 Interface Module
C.3 EXT Mode
This mode is used in applications of X.21 networks where the system timing
is provided by the X.21 network. The IR-X.21 module has an internal buffer
to compensate for the phase delay introduced to the system by the line
delay between the two modems. The buffer is a 16-bit FIFO connected as
shown in Figure C-4. When the modem's clock mode is EXT, the JP2 jumper
must be set to EXT (see Figure C-3).
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Zobrazit stránku 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 65 66

Komentáře k této Příručce

Žádné komentáře