Installation and Operation Manual Chapter 4 Configuration
IPmux-24 Ver. 1.5 Configuring IPmux-24 for Operation 4-27
Max capability advertised (Maximum capability to be advertised during the
autonegotiation process):
10BaseT Half Duplex
10BaseT Full Duplex
100BaseT Half Duplex
100BaseT Full Duplex
1000BaseX Full Duplex
Default type (Rate and duplex mode, if the autonegotiation is disabled):
10BaseT Half Duplex
10BaseT Full Duplex
100BaseT Half Duplex
100BaseT Full Duplex
1000BaseX Full Duplex
When autonegotiation protocols do not support each other, this degrades the
connection to a half-duplex mode.
In order to avoid this, disable
autonegotiation and configure the ports manually. Half-duplex degradation
also occurs when autonegotiation is enabled at one port and disabled at the
opposite port.
Half-duplex operation in the IPmux-24 network port is not recommended
when transmitting small-size packets, because collisions and backoffs cause
large delay variation and may exceed the delay variation buffer tolerance at
the receiving end, resulting in buffer underflows and errors.
Flow Control (Data flow control method based on Ethernet Pause frames.
IPmux-24 only responds to the Pause frames sent by the peer device,
slowing its transmission rate.):
Enable (Flow control is enabled)
Disable (Flow control is disabled)
Enabling flow control may cause deterioration in the clock and voice traffic
quality.
4. Type S to save your changes.
Notes
Note