ASM-40CD
Dual High-Speed Short-Range Modem Card
Version 1.0
LRS-24 Module
INSTALLATION AND
OPERATION MANUAL
Innovative Access Solutions
Zobrazit stránku 0
1 2 3 4 5 6 ... 75 76

Shrnutí obsahu

Strany 1 - ASM-40CD

ASM-40CDDual High-Speed Short-Range Modem Card Version 1.0LRS-24 ModuleINSTALLATION AND OPERATION MANUAL Innovative Access Solutions

Strany 3

ASM-40CD Ver. 1.0 Configuring ASM-40CD 1 Quick Start Guide If you are familiar with ASM-40CD, use this guide to prepare the unit for operation. 1.

Strany 4 - Product Disposal

Quick Start Guide Installation and Operation Manual 2 Configuring ASM-40CD ASM-40CD Ver. 1.0 Advanced Configuration For further configuration: • C

Strany 5 - Safety Symbols

ASM-40CD Ver. 1.0 i Contents Chapter 1. Introduction 1.1 Overview...

Strany 6 - Handling Energized Products

Table of Contents Installation and Operation Manual ii ASM-40CD Ver. 1.0 Chapter 4. Troubleshooting and Diagnostics 4.1 Loopback Tests...

Strany 7

ASM-40CD Ver. 1.0 Overview 1-1 Chapter 1 Introduction 1.1 Overview ASM-40CD is a card containing two independent synchronous high-speed short range

Strany 8 - Attention

Chapter 1 Introduction Installation and Operation Manual 1-2 Overview ASM-40CD Ver. 1.0 Figure 1-2 shows a power feeding application, where ASM-40C

Strany 9 - FCC-15 User Information

Installation and Operation Manual Chapter 1 Introduction ASM-40CD Ver. 1.0 Physical Description 1-3 Remote Power Feeding The phantom current optio

Strany 10

Chapter 1 Introduction Installation and Operation Manual 1-4 Physical Description ASM-40CD Ver. 1.0 P12P10P11POWERSYNC LOSS1SYNC LOSS2RTS1DCD1RTS2

Strany 11 - Quick Start Guide

Installation and Operation Manual Chapter 1 Introduction ASM-40CD Ver. 1.0 Functional Description 1-5 1.3 Functional Description Block Diagram Fig

Strany 13 - Contents

Chapter 1 Introduction Installation and Operation Manual 1-6 Functional Description ASM-40CD Ver. 1.0 The setting of XMT clock depends on: • Int

Strany 14

Installation and Operation Manual Chapter 1 Introduction ASM-40CD Ver. 1.0 Functional Description 1-7 XMTFIFORCVFIFOTXRXInternalExternalReceiveInt

Strany 15 - Introduction

Chapter 1 Introduction Installation and Operation Manual 1-8 Technical Specifications ASM-40CD Ver. 1.0 Table 1-2. ASM-40CD Configurable Paramete

Strany 16 - Features

Installation and Operation Manual Chapter 1 Introduction ASM-40CD Ver. 1.0 Technical Specifications 1-9 DTE Interface Type V.24, V.35, V.36, X.21,

Strany 17 - 1.2 Physical Description

Chapter 1 Introduction Installation and Operation Manual 1-10 Technical Specifications ASM-40CD Ver. 1.0 Power Supply Voltage ±5V Power Consumpti

Strany 18 - Figure 1-4

ASM-40CD Ver. 1.0 Package Contents 2-1 Chapter 2 Installation and Operation This chapter provides information for: • Installation of the ASM-40CD

Strany 19 - 1.3 Functional Description

Chapter 2 Installation and Operation Installation and Operation Manual 2-2 Installing the ASM-40CD Card ASM-40CD Ver. 1.0 • Splitter cable for co

Strany 20

Installation and Operation Manual Chapter 2 Installation and Operation ASM-40CD Ver. 1.0 Installing the Interface Module 2-3 Table 2-1. ASM-40CD

Strany 21 - Configurable Parameters

Chapter 2 Installation and Operation Installation and Operation Manual 2-4 Installing the Interface Module ASM-40CD Ver. 1.0 Table 2-3. Interface

Strany 22

Installation and Operation Manual Chapter 2 Installation and Operation ASM-40CD Ver. 1.0 Interfaces and Connections 2-5 Setting Internal Jumpers T

Strany 23

ASM-40CD Dual High-Speed Short-Range Modem Card Version 1.0 Installation and Operation Manual Notice This manual contains information that is propr

Strany 24 - Environment

Chapter 2 Installation and Operation Installation and Operation Manual 2-6 Operating the ASM-40CD ASM-40CD Ver. 1.0 Connecting the Line and DTE 

Strany 25 - Installation and Operation

Installation and Operation Manual Chapter 2 Installation and Operation ASM-40CD Ver. 1.0 Operating the ASM-40CD 2-7 Table 2-5. ASM-40CD LEDs ID C

Strany 26 - Figure 2-1

Chapter 2 Installation and Operation Installation and Operation Manual 2-8 Operating the ASM-40CD ASM-40CD Ver. 1.0 Powering ASM-40CD Up  To po

Strany 27 - Interface Module Inspection

ASM-40CD Ver. 1.0 Introduction 3-1 Chapter 3 Configuration This chapter describes how to configure the ASM-40CD modem installed in the LRS-24 hub

Strany 28 - LRSI-F-14

Chapter 3 Configuration Installation and Operation Manual 3-2 Entering Commands ASM-40CD Ver. 1.0 Table 3-1. LRS-24 Screens Screen Indication LR

Strany 29 - Setting Internal Jumpers

Installation and Operation Manual Chapter 3 Configuration ASM-40CD Ver. 1.0 Entering Commands 3-3 Table 3-2. Screen Access Commands Command Func

Strany 30 - 2.6 Operating the ASM-40CD

Chapter 3 Configuration Installation and Operation Manual 3-4 Configuring the Modem ASM-40CD Ver. 1.0 3.4 Default Factory Settings The factory se

Strany 31 - Figure 2-5. ASM-40CD LEDs

ASM-40CD Ver. 1.0 Loopback Tests 4-1 Chapter 4 Troubleshooting and Diagnostics This chapter discusses: • Types of loopback tests • Internal BERT

Strany 32 - Normal Operation

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-2 Loopback Tests ASM-40CD Ver. 1.0 While a loopback connection is se

Strany 33 - Configuration

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Loopback Tests 4-3 DTE 2DTE 1XMTRCVDataDataDataXMTRC

Strany 34 - Chapter 4

Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the ASM-40CD to be delivered hereunder shall be free of defects in material and wo

Strany 35 - Navigating the Menu

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-4 Loopback Tests ASM-40CD Ver. 1.0 Figure 4-2. ASM-40CD Remote Dig

Strany 36 - 3.5 Configuring the Modem

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Setting Loopback and BER Tests 4-5 4.2 Internal BER

Strany 37 - Diagnostics

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-6 Setting Loopback and BER Tests ASM-40CD Ver. 1.0 MODEM DIAGNOSTIC

Strany 38 - Local Analog Loopback (LLB)

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Viewing Alarm Status 4-7 Parameter Type Function

Strany 39

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-8 Viewing Alarm Status ASM-40CD Ver. 1.0 MODEM ALARM STATUS MODEM

Strany 40 - Local Digital Loopback (DIG)

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Viewing Alarm Buffer Messages 4-9 Parameter Type F

Strany 41

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-10 Troubleshooting ASM-40CD Ver. 1.0 Table 4-3. ASM-40CD Alarm Mess

Strany 42

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Troubleshooting 4-11 Table 4-5. Troubleshooting Usi

Strany 43 - 4.4 Viewing Alarm Status

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-12 Troubleshooting ASM-40CD Ver. 1.0 StartSet local ASM-40CDto LLBOK

Strany 44 - Table 4-2

Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics ASM-40CD Ver. 1.0 Troubleshooting 4-13 OK? Line isconnected pro

Strany 45 - . Table 4-3

General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications produc

Strany 46 - Table 4-5

Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual 4-14 Troubleshooting ASM-40CD Ver. 1.0 OK?OK?2Local ASM-40CDmodem and

Strany 47

ASM-40CD Ver. 1.0 Introduction A-1 Appendix A IR-ETH Ethernet Card A.1 Introduction The IR-ETH Ethernet card is a bridge that converts Ethernet el

Strany 48

Appendix A IR-ETH Ethernet Card Installation and Operation Manual A-2 Technical Specifications ASM-40CD Ver. 1.0 Physical Description Figure A-2 s

Strany 49

Installation and Operation Manual Appendix A IR-ETH Ethernet Card ASM-40CD Ver. 1.0 Installation and Operation A-3 A.3 Installation and Operation

Strany 50

Appendix A IR-ETH Ethernet Card Installation and Operation Manual A-4 Installation and Operation ASM-40CD Ver. 1.0 Installing the Interface Module

Strany 51 - IR-ETH Ethernet Card

Installation and Operation Manual Appendix A IR-ETH Ethernet Card ASM-40CD Ver. 1.0 Installation and Operation A-5 Installing the Hub  To insta

Strany 52 - A.2 Technical Specifications

Appendix A IR-ETH Ethernet Card Installation and Operation Manual A-6 Installation and Operation ASM-40CD Ver. 1.0

Strany 53 - Installing the IR-ETH Card

ASM-40CD Ver. 1.0 Application B-1 Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module B.1 Introduction The IR-ETH/QN interface module includes a high

Strany 54 - Figure A-4

Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module Installation and Operation Manual B-2 Technical Specifications ASM-40CD Ver. 1.0 Customer Premise

Strany 55 - LED Indicators

Installation and Operation Manual Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module ASM-40CD Ver. 1.0 Installation and Operation B-3 B.4 Installati

Strany 56

Handling Energized Products General Safety Practices Do not touch or tamper with the power supply when the power cord is connected. Line voltages ma

Strany 57 - Interface Module

Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module Installation and Operation Manual B-4 Installation and Operation ASM-40CD Ver. 1.0 Section Name

Strany 58 - B.3 Technical Specifications

Installation and Operation Manual Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module ASM-40CD Ver. 1.0 Installation and Operation B-5 Installing the

Strany 59 - Configuring IR-ETH/QN

Appendix B IR-ETH/QN (IR-ETH/Q) Interface Module Installation and Operation Manual B-6 Installation and Operation ASM-40CD Ver. 1.0 Installing the

Strany 60

ASM-40CD Ver. 1.0 Modem Advanced Setup C-1 Appendix C Command List This chapter lists: • Commands to access screens:  Modem advanced setup 

Strany 61

Appendix C Command List Installation and Operation Manual C-2 Modem Setup ASM-40CD Ver. 1.0 Figure C-1. Modem Advanced Setup Screen Bolded rows i

Strany 62

Installation and Operation Manual Appendix C Command List ASM-40CD Ver. 1.0 Modem Setup C-3 MODEM SETUP MODEM NAME : ASM 40CD

Strany 63 - Command List

Appendix C Command List Installation and Operation Manual C-4 Modem Status ASM-40CD Ver. 1.0 Parameter Type Function Options Option Indicates

Strany 64 - C.2 Modem Setup

Installation and Operation Manual Appendix C Command List ASM-40CD Ver. 1.0 Modem Status C-5 MODEM STATUS MODEM NAME : ASM 40CD (m) DEFINE

Strany 65 - Clock mode of both

Appendix C Command List Installation and Operation Manual C-6 Modem Log File ASM-40CD Ver. 1.0 Parameter Type Function Option Option indicate

Strany 66 - C.3 Modem Status

Installation and Operation Manual Appendix C Command List ASM-40CD Ver. 1.0 Modem Log File C-7 MODEM LOG FILE MODEM NAME : ASM40CD(m) DEFINE

Strany 67 - Table C-3

Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services

Strany 68 - C.4 Modem Log File

Appendix C Command List Installation and Operation Manual C-8 Modem Log File ASM-40CD Ver. 1.0

Strany 69

24 Raoul Wallenberg Street, Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax +972-3-6483331, +972-3-6498250 E-mail: [email protected], Web site: http://

Strany 71 - Customer Response Form

Error Report  Incompatibility with product  Difficulty in understanding text  Regulatory information (Safety, Compliance, Warnings, etc.)  Difficu

Strany 74

Publication No. 695-202-05/07 International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 647

Strany 75

there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors. To reduce the risk of fire

Strany 76 - Innovative Access Solutions

FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the